Customization: | Available |
---|---|
Theory: | Pressure Steam |
Type: | Pressure Steam Sterilization Equipments |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Adopts microcomputer control technology, touch screen operation, the whole process (pulsevacuum, heating, sterilization, exhaust steam, vacuum drying) procedures automatically run.
2. Touch screen automatically displays operating status, temperature, pressure, time and other parameters and fault alarm information.
3. Has 4 sterilization procedures including instruments, dressings, luminal instruments, rubber, liquid and custom, BD test and vacuum test for users to choose.
4. Built-in vacuum pump, three times (can be set) pulsevacuum, vacuum degree up to -0.090mpa can be fully pumped out of dressings and class A cavity instruments.
5. Built-in high efficiency steam generator, can quickly produce constant pressure steam, do not pollute sterilized goods.
6. Vacuum drying system, fabric dryness less than 1%, instrument dryness less than 0.1%
7. 0.22μm bacterial air filter.Ensure that the air breaking the vacuum is sterile air to avoid re-contamination
8. Optional configuration of micro printer, real-time sterilization process and fault alarm information.
Safety device:
1. Overtemperature protection device: when the temperature of the pot exceeds the set temperature, the system automatically cuts off the heating power and displays an alarm.
2. Door safety interlocking device: only when the door is closed in place, the program can start;The door will not open when there is dangerous pressure in the inner chamber.
3. Double overpressure protection: automatic pressure relief valve, pressure exceeds the design pressure, the safety valve opens to release pressure;Overpressure automatic protection control, pressure exceeds the set pressure, automatic exhaust pressure relief, display alarm.
4. Low water level alarm device: the water level is lower than the specified water level, automatically cut off the heating, display alarm
Technical parameters:
1. Design pressure: -0.1/0.3MPa;
2. Rated working pressure: 0.23MPa
3. Ultimate vacuum: -0.096MPa
4. Pressure display accuracy: 0.1kpa
5. Sterilization temperature: 105 ~ 136ºC
6. Temperature display accuracy 0.1ºC
7. Maximum temperature: 136ºC
8. Temperature uniformity: ≤±0.5ºC;
9. Cavity material: SUS304 stainless steel
Mode | volume | Chamber size | Overall dimensions | Weight | POWER |
(L) | (Φ×L) | (L×W×H) | Kg | ||
YMST-45B | 45 | 316×590 | 850×600×520 | 65 | 220V 50Hz 3.6Kw |
YMST-60B | 60 | 380×500 | 985×600×1450 | 105 | 380V 50Hz 5.7Kw |
YMST-80B | 80 | 380×700 | 985×600×1450 | 120 | 380V 50Hz 5.7Kw |
YMST-135B | 135 | 500×700 | 1000×710×1550 | 200 | 380V 50Hz 9.35Kw |
YMST-185B | 185 | 500×950 | 1250×850×1700 | 230 | 380V 50Hz 10.8Kw |
YMST-300B | 300 | 630×1000 | 1350×950×1750 | 350 | 380V 50Hz 12Kw |