Wfx-220A/B Atomic Absorption Spectrophotometer

Product Details
Customization: Available
After-sales Service: Online
Application: Industrial
Still deciding? Get samples of US$ 18000/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Wfx-220A/B Atomic Absorption Spectrophotometer
  • Wfx-220A/B Atomic Absorption Spectrophotometer
  • Wfx-220A/B Atomic Absorption Spectrophotometer
  • Wfx-220A/B Atomic Absorption Spectrophotometer
  • Wfx-220A/B Atomic Absorption Spectrophotometer
  • Wfx-220A/B Atomic Absorption Spectrophotometer
Find Similar Products

Basic Info.

Model NO.
WFX-220A/B
Warranty
1 Year
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
Classic Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
Prism Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Non-Customized
Temperature Area
Column Oven, Sampler, Detector
Temperature Range
15ºC ~399ºC
Temperature Accuracy
±0.1ºC (Measured at 200ºC)
Detection Limit
Dt≤1×10-10 G/S
Baseline Drift
≤2×10-12 a/H
Linear Range
≥106
Max. Limit Temperature
400ºC
Voltage
220V~±22V 50Hz±0.5Hz
Power
≤1500W
Package Size
945mm×655mm×750mm
G.W
70kg
Transport Package
Export Box
Specification
WFX-220A/B
Trademark
YBOTECH
Origin
China
HS Code
9027300090
Production Capacity
500000PCS/Year

Packaging & Delivery

Package Size
120.00cm * 60.00cm * 60.00cm
Package Gross Weight
100.000kg

Product Description

Wfx-220A/B Atomic Absorption Spectrophotometer
EATURES
Higher Reliability
·More than 40 years experience in AAS R&D and manufacturing
·Aberration eliminated C-T type monochromator with stable performance
·Modular electronic circuits design with easy operation and maintenance 
·Reliable gas-liquid separator and fuel gas filter device provide the robustness even in high humid and harsh environment. 

Higher Safety
·Intelligent feedback detection technique, real-time monitors the lamp current and protects the hollow cathode lamps.
·Simple structure modular gas supply system provides lower fault rate, higher safety and reliability.
·High precision mass flow controller and stable electronics in flame system control the fuel flow accurately. Temperature control protection system together with dual air circuit breakers in GF system, effectively prevent current overload or abnormal temperature rise.  
·Multiple safety interlock device and prompt information display prevent possible dangers.

More easy to use
·Unique light source system,with 8-lamp turret fully automatic change and optimization,supports 1 lamp working and 7 lamps preheating in the same time. 
·Easy changing emission burner for easily ionized elements such as K, Na, etc., with linear range 3 times that of normal flame.
·Temperature control modes in graphite furnace analysis can be switched over easily between optical control and constant voltage control, according to different elements and graphite tubes, for the best results and extending the lifetime of graphite tubes. 
·One-click automatic optimization, easy analytical condition setting, expert database support, for easy operation with no worries.

Fewer Faults
·Hamamatsu's high performance PMT as the detector.
·Molding PPS spray chamber has high chemical stability, withstanding high temperature and strong acids etc..  
·The communication system is based on the mature bussing technique. It improves anti-jamming capability and data transmission reliability. 

SPECIFICATIONS
Wavelength Range
· 190nm ~ 900nm

Light Source
· 8-lamp turret automatically rotates and aligns
· 2 positions for High performance lamp.
· 8-lamp power on and multiple lamp preheat at the same time.
· Lamp current range: 0~15mA

Optical System
·Czerny-Turner monochromator
·Diffraction Grating:Groove 1800lines/mm,blaze wavelength 250nm
·Focal Length:277mm
·Spectral Bandwidth:    0.1nm, 0.2nm, 0.4nm, 0.8nm, 1.6nm 
·automatically change(Model A)
·0.1nm, 0.2nm, 0.4nm, 1.2nm automatically change(Model B)
·Automatic peak-picking, automatic spectral bandwidth setting, automatic energy and wavelength optimization.

Flame System
·10cm Ti burner head for air-acetylene flame, emission burner provided.
·Burner head height and horizontal position automatic adjustment, with burner angle rotatable.(Model A)
·Burner head height push-button adjustable and horizontal position manually adjusted, with burner angle rotatable.(Model B)
·Direct forming spray chamber with corrosion-resistant material PPS
·Automatic ignition with high precision mass flow control system, realizing fully automated fuel gas flow control and adjustment. 

Graphite Furnace System(Type A)
·Longitudinal heating GF system with temperature up to 3000ºC, heating rate more than 2500ºC/s.
·Two temperature control modes selectable: optical and constant voltage. Both slope and stepped temperature programming are available. 
·Fully automatic GF height and horizontal position setting and optimization.
·Inner gas, external gas and make up gas are controlled separately. Circulating water and gas flows monitoring system is equipped. 
·Different types of graphite tubes can be used. 

Safety Protection
·Full package of safety protection measures, with hardware and software dual alarm system.
·Real-time monitoring for flame condition and air pressure etc., with automatic flame shutting down, gas supply cutting off and activating alarm when abnormal detected,such as ignition failure, fuel gas leakage, flow control error, etc.
·Real-time monitoring for GF conditions and heating program etc., with automatic power cut-off and alarm when abnormal detected, such as water and gas control error, graphite tube installation mistake, and temperature control problem etc..

Background Correction
·D2 lamp background correction, with correction ability more than 30 times.
·S-H background correction, with correction ability more than 30 times.

Software and Communication
·Intelligent operation software compatible to WinXP, Win7, Win8, Win10.
·One-key operation for instrument optimization, supporting multi-task analysis. 
·Automatic curve fitting, automatic re-slope, automatic concentration calculation, etc.
·Repeat measure 1~99 times, automatic calculation of Average Value, Standard Deviation, RSD, etc..
·Standard USB communication port.

Power Supply
Main Unit for model A:Single phase AC, 110V/220V,max power consumption: 0.2kVA
Main Unit for model B:Single phase AC, 110V/220V,max power consumption: 0.15kVA
GF Power Supply for model A:Single phase AC, 220V,max power consumption: 5.5kVA

Dimensions and Weight
    Main Unit for Type A:1020mm(L)×530mm(W)×500mm(H),85kg
    Main Unit for Type B:1020mm(L)×530mm(W)×500mm(H),80kg
    GF Power Supply for Type A: 350mm(L)×490mm(W)×430mm(H),40kg

 
Main components Basit Mainframe
Flame Atomisation Platform
Flame Accessories
Graphite Furnace Atomisation Platform
Graphite Furnaces Accessories
Autosampler
Air Compressor
Cooling Circulating Water
Options Hollow Cathode Lamp
Computer
Printer
Wfx-220A/B Atomic Absorption SpectrophotometerWfx-220A/B Atomic Absorption SpectrophotometerWfx-220A/B Atomic Absorption SpectrophotometerWfx-220A/B Atomic Absorption SpectrophotometerWfx-220A/B Atomic Absorption SpectrophotometerWfx-220A/B Atomic Absorption Spectrophotometer
Wfx-220A/B Atomic Absorption Spectrophotometer
Wfx-220A/B Atomic Absorption SpectrophotometerWfx-220A/B Atomic Absorption SpectrophotometerWfx-220A/B Atomic Absorption Spectrophotometer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More