Colony Counter, Cell Counter

Product Details
Customization: Available
After-sales Service: Online
Sample Type: Liquid
Still deciding? Get samples of US$ 60/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Trading Company
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Colony Counter, Cell Counter
  • Colony Counter, Cell Counter
  • Colony Counter, Cell Counter
  • Colony Counter, Cell Counter
  • Colony Counter, Cell Counter
  • Colony Counter, Cell Counter
Find Similar Products

Basic Info.

Model NO.
JL-1
Processing Method
Screening
Warranty
1 Year
Environment
Normal Pressure and Temperature
Display
Digital Display
Performance
Automatic
Power Supply
220V
Weight
0-50kg
Certification
CE, RoHS
Customized
Non-Customized
Power Consumption
< 20W
Magnification
3X/9X
Counting Capacity
0 ~ 999
Voice Reading
Y/N
Charging Function
Y/N
Transport Package
Cardboard Box
Specification
110mm
Trademark
Ultrassay
Origin
China
HS Code
9027801990
Production Capacity
500000PCS/Year

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 15.00cm
Package Gross Weight
2.500kg

Product Description

Colony Counter, Cell CounterColony counter is A digital display type semi-automatic bacterial testing instrument. It is composed of counter, probe and counter pool. The counter is designed and manufactured by CMOS integrated circuit. In the black deep background counting tank, the side lighting of the energy-saving annular fluorescent lamp is adopted, and the colony comparison is clear. According to the bacterial count test procedure, the instrument display is designed with three digits. When the number of colony growth in a petri dish exceeds 300, the test sample should be diluted and redone to ensure the accuracy of the count. This instrument can lighten the labor intensity of the experimenter, improve the work efficiency and work quality. Products are widely used in food, beverage, drugs, biological products, sanitary products, drinking water, industrial waste water, clinical specimens in the number of bacteria test. It is a necessary instrument for health and epidemic prevention stations, environmental monitoring stations, food and hygiene supervision and inspection stations, hospitals, biological products laboratories, drug testing stations, food factories, daily chemical plants, universities and research institutes.

Specification
Model JL-1 JL-2 JL-1C JL-2C
Power Supply 220V± 10%, 50 hz
Power Consumption < 20W
Magnification 3X/9X
Counting Capacity 0 ~ 999
Diameter of pool 110mm
Voice Reading No Yes No Yes
Charging Function No Yes
 

Use Instructions:

A. Switch on the power supply and turn on the light in the counting pool. Throughout 001 &; Insert the probe plug into the socket of the instrument and press. Reset & throughout; Set the key to zero to make the instrument work.
B. put in the culture dish to be tested.
C. count the colonies one by one on the bottom of the petri dish with a probe pen. Every point should be heard. Du & throughout; Sound just explains effective, otherwise should focal point. At this point, the colony at the point is colored and the Numbers add up automatically.
D. check carefully with a magnifying glass to make sure that no omissions are found and that the count is complete.
E. the number in the display screen is the colony number of the petri dish.
F. record the Numbers and remove the petri dish. According to the & other; Reset & throughout; Key, screen into the initial state.
Matters needing attention
A. the instrument should be placed on a flat and firm surface for use.
B. Do not tilt the probe too much when counting colony. The number will be input when the probe is pressed down gently until there is a sense of bounce.
C. The instrument should be moisture-proof, shock proof, direct sunlight exposure, acid and alkali erosion proof, and dust cover should be added after use.
D. pay attention to prevent bacterial culture from contaminating the counting tank.
E. neither the instrument nor the probe can be disassembled at will. If the fault is found, experienced technicians should be asked to repair.

Colony Counter, Cell CounterColony Counter, Cell CounterColony Counter, Cell CounterColony Counter, Cell CounterColony Counter, Cell CounterColony Counter, Cell CounterColony Counter, Cell CounterColony Counter, Cell Counter
Colony Counter, Cell CounterColony Counter, Cell CounterColony Counter, Cell Counter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More