• Eqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for Laboratory
  • Eqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for Laboratory
  • Eqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for Laboratory
  • Eqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for Laboratory
  • Eqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for Laboratory

Eqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for Laboratory

Classification: Biological Diagnostics
Type: Real-Time Qpcr System
Certification: CE, FDA, EEC, MSDS, ISO13485
Group: All
Reaction Volume: 5 - 100 μl
Light Source: 2 or 4 Monochrome Efficient LEDs
Samples:
US$ 8000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
eQmini
Optical Detector
Pd
Thermal Cycling Tech
Peltier
Maximum Ramp Rate
8ºC/S
Power
220VAC, 50/60Hz
Dimension
205×190×98 mm
Transport Package
Export Box
Specification
16 samples per run
Trademark
ultrassay
Origin
China
HS Code
9027501000
Production Capacity
500000PCS/Year

Product Description

Eqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for LaboratoryeQMini series Real-time PCR System

Feature:
Ultrassay eQMini series Real-time PCR System is a high-performance model meticulously improved on the basis of the eQ164CP classic model, The instrument comes with a full-color touch screen and self-developed operation analysis software. It does not require a computer and realizes independent operation, program editing, data viewing and data analysis. The compact body design and powerful software functions fully meet the various needs of users for small-throughput experiments and out door operations. 

Advantages:
1. Touch screen control, with software, efficient and convenient.
2. Simple operation interface, powerful software function.
3. Strong fluorescence signal, low background noise, high sensitivity.
4. Unique design of block, rapid temperature change, good uniformity.


Application scope:
This system is optimized for configuration, especially for sample size, rapid on-site inspection and quarantine, disease prevention and control (such as African swine fever, bird flu, etc.), food safety, agriculture, forestry and biochemistry.

Technical Specification
Model eQMini-A eQMini-B eQMini-C
Sample volume 16*0.2ml single tube or 8-strip transparent tube (except for white opaque tube), you can mark the tube with markers on the cover of the tube.
Applicable reagents This system is an open platform, suitable for various real-time PCR reagents, including fast extraction reagents, non-extraction reagents, or direct amplification reagents and other low-concentration PCR reagent.
Reaction volume 5-100ul
Dynamic range 1-1010 Copies
Color wavelength 400 - 700nm
Optical sensor PD
Dyes CH1: FAM, SYBR Green I;
CH2: HEX, JOE, VIC, ROX.
CH1: FAM, SYBR Green I;
CH2: HEX, JOE, VIC, ROX;
CH3: ROX, CALRED;
CH4: CY5, QUASAR
Sensitivity 1 Copy
Rn 0.998
CV 0.6%
Block setting range 10-99.9ºC
Temperature control mode Tube mode, Real temperature of simulated reagent
Refrigeration Peltier
Precision of temperature control 0.1ºC
Display resolution 0.1ºC
Temperature accuracy ±0.2ºC
Temperature uniformity 0.2ºC
Max. ramping rate 4ºC/s
Avg. ramping rate 2.5ºC/s (50ºC - 90ºC)
Hot lid 30ºC-105ºC
Operating system Windows 7/10
Communication Interface RS232/USB
Software functions Built-in two-steps, three-steps, LAMP, RPA methods' PCR program templates, free extraction reagent PCR program template and other common ones.
It has functions of system setting (password permission), experimental parameter settings, sample information input, operation management, data export EXCEL, general view of PCR program, real-time amplification curve display, channel crosstalk correction, criterion setting, automatic report, curve capture, etc.
Analytical function Standard curve, relative quantitative curve and melting curve (HRM)
Operating ambient Ambient temperature: 10-30, relative humidity: 20-85% RH, 
Input power 100-240V - 300VA
Dimension 265x334x172 (A4 paper size)
Net weight 6.8kg
Eqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for Laboratory
 Eqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for LaboratoryEqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for LaboratoryEqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for LaboratoryEqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for LaboratoryEqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for Laboratory
Eqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for Laboratory

 
Eqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for LaboratoryEqmini Real Time PCR Machine Thermal Cycler PCR Amplifier System for Laboratory

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now